Control the sensitivity of the device AI detection
Supported Algorithm Types
| Algorithm Name | algorithm_type | Description |
|---|---|---|
| Flame Alarm | fire_alarm | |
| Smoke Alarm | smoke_alarm | |
| Human Detection | human_detection | |
| Motion Detection | human_movement |
Production: https://open.eye4cloud.com/{{open_id}}/open/v1/device/sensitivity| Field Name | Required | Type | Description |
|---|---|---|---|
| device_id | Yes | string | Device ID |
| timestamp | Yes | int64 | Timestamp in seconds |
| nonce | Yes | string | Random string, 8-20 characters |
| sign | Yes | string | See "Sign Generation Examples" for the implementation details |
| password | No | string | Device password; if omitted, the password registered for the device on the Open Platform is used |
| algorithm_type | Yes | string | See the table above for algorithm types |
| sensitivity_type | Yes | string | Sensitivity: 0=low, 1=medium, 2=high |
| data | No | string | Device DATA; an empty string can be passed |
| imei | No | string | Device IMEI; an empty string can be passed |
curl 'https://open.eye4cloud.com/{{open_id}}/open/v1/device/sensitivity' \
-H 'Content-Type: application/json' \
--data-raw '{
"device_id": "DEMO_DEVICE_001",
"timestamp": 1758867195,
"nonce": "",
"sign": "",
"password": "",
"algorithm_type": "fire_alarm",
"sensitivity_type":1
}'
| Field Name | Type | Description |
|---|---|---|
| error_code | int | Status code: 0 indicates success; other values indicate an error |
| error_message | string | Error message; success indicates a normal response |
| data | object | {} |
Example:
{
"error_code": 0,
"error_message": "success",
"error_tips": "",
"data": {
}
}